Publication date: Available online 4 September 2020Source: Academic RadiologyAuthor(s): Marc Jutras, Leilynaz Malekafzali, Sunghan Jung, Priya Das, Sadia Raheez Qamar, Faisal Khosa
Publication date: Available online 3 September 2020Source: Academic RadiologyAuthor(s): Mark M Hammer, Suzanne C Byrne, Chung Yin Kong
Publication date: Available online 3 September 2020Source: Academic RadiologyAuthor(s): Sumera Ali, Hunter D. Vines, Shelly Y. Lensing, Roopa Ram, Di Chang, Linda A. Deloney, Philip J. Kenney
Mark above section as read
Publication date: Available online 6 September 2020Source: Clinical ImagingAuthor(s): Dawood Tafti, Erica Kao, Joseph F. Alderete, Nathan D. Cecava
Publication date: Available online 6 September 2020Source: Clinical ImagingAuthor(s): Maansi Parekh
Publication date: Available online 4 September 2020Source: Clinical ImagingAuthor(s): Carita Tsoi, Chris S.C. Tsai, Eric K.C. Law, Ryan K.L. Lee, Alex W.H. Ng, James F. Griffith
Mark above section as read
Abstract Purpose Almost all radiolabellings of antibodies with 89Zr currently employ the hexadentate chelator desferrioxamine (DFO). However, DFO can lead to unwanted uptake of 89Zr in bones due to instability of the resulting metal complex. DFO*-NCS and the squaramide ester of DFO, DFOSq, are novel analogues that gave more stable 89Zr complexes than DFO in pilot experiments. Here, we directly compare these linker-chelator systems to...
Abstract Purpose To determine thresholds for amyloid beta pathology and evaluate associations with longitudinal memory performance with the aim to identify a grey zone of early amyloid beta accumulation and investigate its clinical relevance. Methods We included 162 cognitively normal participants with subjective cognitive decline from the SCIENCe...
Mark above section as read
Objectives Magnetic resonance imaging guidance has been sporadically reported for renal tumor cryoablation (CA); therefore, clinical experience with this modality is still limited. The aim of this study is to retrospectively analyze our 10-year experience with renal tumor CA performed on a 1.5 T magnetic resonance imaging unit with the intent of reporting procedural safety and oncologic outcomes. Materials and Methods We included 143 patients (102 men; 41 women; median age, 73 years;...
Mark above section as read
Mark above section as read
Publication date: Available online 6 September 2020Source: NeuroImageAuthor(s): Zhengshi Yang, Xiaowei Zhuang, Karthik Sreenivasan, Virendra Mishra, Dietmar Cordes, for the Alzheimer's Disease Neuroimaging Initiative
Publication date: Available online 6 September 2020Source: NeuroImageAuthor(s): Stefan Koelsch
Publication date: Available online 5 September 2020Source: NeuroImageAuthor(s): Rikkert Hindriks
Publication date: Available online 5 September 2020Source: NeuroImageAuthor(s): Hanh Vu, Hyun-Chul Kim, Minyoung Jung, Jong-Hwan Lee
Publication date: Available online 5 September 2020Source: NeuroImageAuthor(s): Osnat Volovyk, Assaf Tal
Publication date: Available online 5 September 2020Source: NeuroImageAuthor(s): Roberto Viviani, Lisa Dommes, Julia E. Bosch, Karin Labek
Publication date: Available online 3 September 2020Source: NeuroImageAuthor(s): Dr. Michael Breakspear
Mark above section as read
Mark above section as read
Abstract Central venous lines may require contrast injection under fluoroscopy to evaluate for dysfunction such as occlusion, fibrin sheath development or catheter fracture. Rarely, some patients may be too ill to travel to the interventional radiology suite for this examination. We present a case utilizing contrast-enhanced ultrasound (CEUS) at the bedside to assess catheter integrity in a critically ill infant with a large intra-abdominal fluid collection. CEUS demonstrated...
Abstract Background Pediatric bone marrow assessment by MRI is challenging and primarily experiential and qualitative, with a paucity of clinically useful quantitative imaging techniques. Objective MRI fat fraction (MRI-FF) is a technique used to quantify the degree of fat in other organ systems. The purpose of this study was to assess whether MRI-FF...
Abstract Anomalous origin of the coronary arteries, though uncommon, is of great clinical concern. It can be the cause of sudden cardiac death and abnormal cardiac hemodynamics. Advances in electrocardiographically (ECG)-gated multi-detector CT have increased diagnostic accuracy in detecting anomalous origin of coronary arteries and their interarterial and intramural courses. Recent advances in multi-detector CT image processing software have allowed the creation of virtual endoluminal...
Mark above section as read
Publication date: Available online 4 September 2020Source: Revista Española de Medicina Nuclear e Imagen MolecularAuthor(s): A. Ruibal Morell
Mark above section as read
Publication date: Available online 4 September 2020Source: Ultrasound in Medicine & BiologyAuthor(s): Xiao-Long Li, Feng Lu, An-Qi Zhu, Dou Du, Yi-Feng Zhang, Le-Hang Guo, Li-Ping Sun, Hui-Xiong Xu
Mark above section as read
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου